Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "ključne besede" (timber connection) .

1 - 2 / 2
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Improved seismic response of light-frame-timber panels with cement-particle-board sheathing of various thicknesses and different configurations of fasteners
Meta Kržan, Tomaž Pazlar, Boštjan Ber, 2022, izvirni znanstveni članek

Povzetek: Due to their comparable fire characteristics and surface preparation, light-frame timber panels using cement-particle boards (CPB) as a sheathing material present a potential alternative to gypsum-fibre boards. An experimental campaign was conducted to evaluate the behaviour of CPB light-frame-timber panels under in-plane lateral loading. Monotonic and cyclic in-plane shear tests were conducted on full-size panels, following preceding tests on the stapled sheathing-to-timber connections used in the panels. The influence of the boards’ thickness and staple geometry on the response of connections and panels was studied, also on panels with an asymmetrical CPB layout, which proved not to have a negative influence on the panels’ lateral load-bearing capacity. Furthermore, in order to improve the seismic response, panels, which had almost twice the number of staples compared to the basic panel, were tested; one variation with two rows of staples, and the other with the staples spaced closer together, such that the spacing distance was halved. The tests revealed a significant, though not proportional, increase in lateral resistance in the strengthened panels. Fastening the CPB with two rows of staples proved the better option, since subsequent failure of the CPB along the connections, as opposed to ductile failure of the staples in the basic panels, proved not to reduce the panels’ deformation capacity. The paper also compares the test results of the connections and panels to analytical results according to Eurocode 5 (EC5), the European code provision for the design of timber structures.
Ključne besede: light-frame timber panels, cement-particle board sheathing, cyclic shear tests, sheathing-to-timber connection, asymmetrical panel, staple spacing distance, EN 1995–1-1, open access
Objavljeno v DiRROS: 31.05.2023; Ogledov: 402; Prenosov: 191
.pdf Celotno besedilo (15,48 MB)
Gradivo ima več datotek! Več...

2.
Mechanical performance of timber connections made of thick flexible polyurethane adhesives
Jaka Gašper Pečnik, Igor Gavrić, Václav Sebera, Meta Kržan, Arkadiusz Kwiecień, BogusŁaw Zając, Boris Azinović, 2021, izvirni znanstveni članek

Povzetek: This study investigates timber connections with flexible polyurethane adhesives, which prove to have the po-tential for timber-adhesive composite structures without mechanical connections for seismic regions. Results of conducted cyclic double lap-shear adhesive timber joints tests were compared with available experimental re-sults on timber connections with standard mechanical dowel-type fasteners and with results of numerical finite element analysis. The study found that the shear strength, elastic stiffness and strength degradation capacity of the flexible adhesive connections were significantly higher compared to mechanical fasteners commonly used in seismic-resistant timber connections. The latter, however, manifested larger ultimate displacements but also yielded at lower displacements.
Ključne besede: flexible adhesive, timber connection, polyurethane, double lap-shear, cyclic loading, energy dissipation, open access
Objavljeno v DiRROS: 19.05.2023; Ogledov: 385; Prenosov: 248
.pdf Celotno besedilo (5,16 MB)
Gradivo ima več datotek! Več...

Iskanje izvedeno v 0.09 sek.
Na vrh