Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "ključne besede" (coupled multi electrode array) .

1 - 2 / 2
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Monitoring the galvanic corrosion of copper–steel coupling in bentonite slurry during the early oxic phase using coupled multielectrode arrays
Tadeja Kosec, Miha Hren, Klara Prijatelj, Bojan Zajec, Nina Gartner, Andraž Legat, 2023, izvirni znanstveni članek

Povzetek: In the case of a two-part container for spent nuclear fuel, consisting of an iron-based inner structure with a copper coating, the potential perforation of copper through minor damage may result in intensive galvanic corrosion between copper and steel. The present work focuses on the corrosion of steel galvanically coupled to copper and exposed to a slightly saline environment under oxic conditions. The electrochemical processes on individual electrodes were monitored by coupled multielectrode arrays (CMEAs). The CMEAs were either in contact with groundwater saturated with bentonite or immersed in groundwater only. Very high galvanic corrosion currents were detected between carbon steel and pure copper in the early oxic phase. Additionally, the use of CMEAs further made it possible to monitor the distribution of cathodic currents around the steel electrode, which behaved anodically. Various microscopy and spectroscopy techniques were applied to identify the modes of corrosion and the type of corrosion products present at the end of the period of exposure.
Ključne besede: copper, steel, bentonite, Aspö groundwater, coupled multi electrode array, electrochemical properties, Raman analysis, corrosion
Objavljeno v DiRROS: 16.11.2023; Ogledov: 351; Prenosov: 57
.pdf Celotno besedilo (1,66 MB)
Gradivo ima več datotek! Več...

2.
Characterization of steel corrosion processes in various blended cements by means of coupled multi-electrode arrays
Miha Hren, Tadeja Kosec, Andraž Legat, 2023, izvirni znanstveni članek

Povzetek: Supplementary cementitious materials can affect the porosity of concrete, pore solution pH and chloride binding, all of which influence the type and magnitude of corrosion damage. Advanced corrosion monitoring techniques are needed to follow the development of corrosion on steel embedded in concrete across space and over time. In this study, coupled multi-electrode arrays (CMEAs) were used to characterise corrosion processes in OPC and three blended cements. Cyclic wetting with chlorides was undertaken to initiate corrosion. The results showed three distinct types of corrosion: localised corrosion (CEM I), localised corrosion that expanded over time (CEM II), and a combination of localised and general corrosion (CEM III and CEM IV). Cathodic locations were also monitored successfully, and the corrosion behaviour was related to total porosity and pH of the pore solution. MicroCT was used to quantify the volume of corroded material, which agreed well with results calculated from the CMEA measurements.
Ključne besede: blended cements, coupled multi-electrode array, corrosion of steel in concrete, supplementary cementitious materials, open access
Objavljeno v DiRROS: 29.05.2023; Ogledov: 274; Prenosov: 174
.pdf Celotno besedilo (12,61 MB)
Gradivo ima več datotek! Več...

Iskanje izvedeno v 0.05 sek.
Na vrh