Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "ključne besede" (brachytherapy) .

1 - 5 / 5
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Prognostic factors of choroidal melanoma in Slovenia, 1986-2008
Boris Jančar, Marjan Budihna, Brigita Drnovšek-Olup, Katrina Novak-Andrejčič, Irena-Hedvika Brovet-Zupančič, Dušica Pahor, 2016, izvirni znanstveni članek

Povzetek: Introduction. Choroidal melanoma is the most common primary malignancy of the eye, which frequently metastasizes. The Cancer Registry of Slovenia reported the incidence of choroid melanoma from 1983 to 2009 as stable, at 7.8 cases/million for men and 7.4/million for women. The aim of the retrospective study was to determinate the prognostic factors of survival for choroidal melanoma patients in Slovenia. Patients and methods. From January 1986 to December 2008 we treated 288 patients with malignant choroidal melanoma; 127 patients were treated by brachytherapy with beta rays emitting ruthenium-106 applicators; 161 patients were treated by enucleation. Results. Patients with tumours thickness < 7.2 mm and base diameter < 16 mm were treated by brachytherapy and had 5- and 10-year overall mortality 13% and 32%, respectively. In enucleated patients, 5- and 10-year mortality was higher, 46% and 69%, respectively, because their tumours were larger. Thirty patients treated by brachytherapy developed local recurrence. Twenty five of 127 patients treated by brachytherapy and 86 of 161 enucleated patients developed distant metastases. Patients of age >/= 60 years had significantly lower survival in both treatment modalities. For patients treated by brachytherapy the diameter of the tumour base and treatment time were independent prognostic factors for overall survival, for patients treated by enucleation age and histological type of tumour were independent prognosticators. In first few years after either of treatments, the melanoma specific annual mortality rate increased, especially in older patients, and then slowly decreased. Conclusions. It seems that particularly younger patients with early tumours can be cured, whereby preference should be given to eyesight preserving brachytherapy over enucleation.
Ključne besede: choroidal melanoma, therapy, brachytherapy, prognostic factors
Objavljeno v DiRROS: 09.05.2024; Ogledov: 102; Prenosov: 59
.pdf Celotno besedilo (624,05 KB)
Gradivo ima več datotek! Več...

2.
Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy
Primož Petrič, Robert Hudej, Noora Al-Hammadi, Barbara Šegedin, 2016, izvirni znanstveni članek

Povzetek: Standard applicators for cervical cancer Brachytherapy (BT) do not always achieve acceptable balance between target volume and normal tissue irradiation. We aimed to develop an innovative method of Targetvolume Density Mapping (TDM) for modelling of novel applicator prototypes with optimal coverage characteristics. Patients and methods. Development of Contour-Analysis Tool 2 (CAT-2) software for TDM generation was the core priority of our task group. Main requests regarding software functionalities were formulated and guided the coding process. Software validation and accuracy check was performed using phantom objects. Concepts and terms for standardized workflow of TDM post-processing and applicator development were introduced. Results. CAT-2 enables applicator-based co-registration of Digital Imaging and Communications in Medicine (DICOM) structures from a sample of cases, generating a TDM with pooled contours in applicator-eye-view. Each TDM voxel is assigned a value, corresponding to the number of target contours encompassing that voxel. Values are converted to grey levels and transformed to DICOM image, which is transported to the treatment planning system. Iso-density contours (IDC) are generated as lines, connecting voxels with same grey levels. Residual Volume at Risk (RVR) is created for each IDC as potential volume that could contain organs at risk. Finally, standard and prototype applicators are applied on the TDM and virtual dose planning is performed. Dose volume histogram (DVH) parameters are recorded for individual IDC and RVR delineations and characteristic curves generated. Optimal applicator configuration is determined in an iterative manner based on comparison of characteristic curves, virtual implant complexities and isodose distributions. Conclusions. Using the TDM approach, virtual applicator prototypes capable of conformal coverage of any target volume, can be modelled. Further systematic assessment, including studies on clinical feasibility, safety and effectiveness are needed before routine use of novel prototypes can be considered.
Ključne besede: cervical cancer, brachytherapy, applicators, virtual modelling
Objavljeno v DiRROS: 09.05.2024; Ogledov: 83; Prenosov: 28
.pdf Celotno besedilo (671,88 KB)

3.
Obstructive urination problems after high-dose-rate brachytherapy boost treatment for prostate cancer are avoidable
Borut Kragelj, 2016, izvirni znanstveni članek

Povzetek: Aiming at improving treatment individualization in patients with prostate cancer treated with combination of external beam radiotherapy and high-dose-rate brachytherapy to boost the dose to prostate (HDRB-B), the objective was to evaluate factors that have potential impact on obstructive urination problems (OUP) after HDRB-B. Patients and methods. In the follow-up study 88 patients consecutively treated with HDRB-B at the Institute of Oncology Ljubljana in the period 2006-2011 were included. The observed outcome was deterioration of OUP (DOUP) during the follow-up period longer than 1 year. Univariate and multivariate relationship analysis between DOUP and potential risk factors (treatment factors, patients% characteristics) was carried out by using binary logistic regression. ROC curve was constructed on predicted values and the area under the curve (AUC) calculated to assess the performance of the multivariate model. Results. Analysis was carried out on 71 patients who completed 3 years of follow-up. DOUP was noted in 13/71 (18.3%) of them. The results of multivariate analysis showed statistically significant relationship between DOUP and anticoagulation treatment (OR 4.86, 95% C.I. limits: 1.21-19.61, p = 0.026). Also minimal dose received by 90% of the urethra volume was close to statistical significance (OR = 1.23; 95% C.I. limits: 0.98-1.07, p = 0.099). The value of AUC was 0.755. Conclusions. The study emphasized the relationship between DOUP and anticoagulation treatment, and suggested the multivariate model with fair predictive performance. This model potentially enables a reduction of DOUP after HDRB-B. It supports the belief that further research should be focused on urethral sphincter as a critical structure for OUP.
Ključne besede: prostate cancer, high-dose-rate brachytherapy boost, urinary stricture, obstructive urination problems
Objavljeno v DiRROS: 30.04.2024; Ogledov: 101; Prenosov: 58
.pdf Celotno besedilo (537,29 KB)
Gradivo ima več datotek! Več...

4.
MRI-assisted cervix cancer brachytherapy pre-planning, based on application in paracervical anaesthesia : final report
Primož Petrič, Robert Hudej, Omar Hanuna, Primož Marolt, Barbara Šegedin, 2014, izvirni znanstveni članek

Povzetek: Background. Optimal applicator insertion is a precondition for the success of cervix cancer brachytherapy (BT). We aimed to assess feasibility and efficacy of MRI-assisted pre-planning, based on applicator insertion in para-cervical anaesthesia (PCA). Patients and methods. Five days prior to BT, the pre-planning procedure was performed in 18 cervix cancer patients: tandem-ring applicator was inserted under PCA, pelvic MRI obtained and applicator removed. Procedure tolerability was assessed. High risk clinical target volume (HR CTV) and organs at risk were delineated on the pre-planning MRI, virtual needles placed at optimal positions, and dose planning performed. At BT, insertion was carried out in subarachnoidal anaesthesia according to pre-planned geometry. Pre-planned and actual treatment parameters were compared. Results. Pre-planning procedure was well tolerated. Median difference between the pre-planned and actual needle insertion depth and position were 2 (0%10) mm and 4 (0%30) degrees, respectively. The differences between the pre-planned and actual geometric and dosimetric parameters were statistically non-significant. All actual needles were positioned inside the HR CTV and outside the organs at risk (OAR). Conclusions. Our pre-planning approach is well tolerated and effective. Pre-planned geometry and dose distribution can be reproduced at BT.
Ključne besede: cervix cancer, pre-planning, image-guided brachytherapy
Objavljeno v DiRROS: 11.04.2024; Ogledov: 166; Prenosov: 65
.pdf Celotno besedilo (753,88 KB)
Gradivo ima več datotek! Več...

5.
Uterine perforation - 5-year experience in 3-D image guided gynaecological brachytherapy at Institute of Oncology Ljubljana
Barbara Šegedin, Jasenka Gugić Kevo, Primož Petrič, 2013, izvirni znanstveni članek

Povzetek: Background. Accurate applicator placement is a precondition for the success of gynaecological brachytherapy (BT). Unrecognized uterine perforation can lead to bleeding, infection, high doses to pelvic organs and underdosage of the target volume, resulting in acute morbidity, long-term complications and reduced chance of cure. We aimed to assess the incidence and clinical characteristics of our cases with uterine perforation, review their management and impact on the treatment course. Patinets and methods. In all patients, treated with utero-vaginal image guided BT for gynaecological cancer between January 2006 and December 2011, the CT/MR images with the applicator in place were reviewed. The incidence of uterine perforations was recorded. Clinical factors that may have predisposed to increased risk of perforation were recorded. Management of perforations and their impact on treatment course was assessed. Results. 219 patients (428 applications) were suitable for analysis. Uterine perforation was found in 13 (3.0%) applications in 10 (4.6%) patients. The most frequent perforation site was posterior uterine wall (n = 9), followed by anterior wall (n = 2) and fundus (n = 2). All cases were managed conservatively, without complications. Prophylactic antibiotics were administered in 8 cases. In 4 patients, abdominal and/or transrectal ultrasound (US) guidance was used on subsequent applications for applicator insertion; adequate applicator placement was achieved and treatment completed as planned in all cases. Conclusions. 3D imaging for BT planning enables accurate identification of uterine perforations. The incidence of perforations at our department is one of the lowest reported in the literature. US guidance of applicator insertion is useful and feasible, allowing to complete the planned treatment even in challenging cases.
Ključne besede: uterine perforation, brachytherapy, 3D imaging, ultrasound guidance
Objavljeno v DiRROS: 22.03.2024; Ogledov: 123; Prenosov: 38
.pdf Celotno besedilo (367,57 KB)

Iskanje izvedeno v 0.11 sek.
Na vrh