Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:Influence of Building Envelope Modeling Parameters on Energy Simulation Results
Avtorji:ID Muhič, Simon (Avtor)
ID Manić, Dimitrije (Avtor)
ID Čikić, Ante (Avtor)
ID Komatina, Mirko (Avtor)
Datoteke:URL URL - Izvorni URL, za dostop obiščite https://www.mdpi.com/2071-1050/17/12/5276
 
.pdf PDF - Predstavitvena datoteka, prenos (1,29 MB)
MD5: 816E0E2661FA253D1208AB53CC1F065A
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo RUDOLFOVO - Rudolfovo – Znanstveno in tehnološko središče Novo mesto
Povzetek:This study investigates the influence of input values for building energy model parameters on simulation results, with the aim of improving the reliability and sustainability of energy performance assessments. Dynamic simulations were conducted in TRNSYS for three theoretical multi-residential buildings, varying parameters such as referent model dimensions, infiltration rates, envelope thermophysical properties, and interior thermal capacitance. The case study, based in Slovenia, demonstrates that glazing-related parameters, particularly the solar heat gain coefficient (g-value), exert the most significant influence—reducing the g-value from 0.62 to 0.22 decreased simulated heating (qH,nd) and cooling (qC,nd) demands by 25% and 95%, respectively. In contrast, referent dimensions for modeled floor area proved least influential. For Building III (BSF = 0.36), dimensional variations altered results by less than ±1%, whereas, for Building I (BSF = 0.62), variations reached up to ±20%. In general, lower shape factors yield more robust energy models that are less sensitive to input deviations. These findings are critical for promoting resource-efficient simulation practices and ensuring that energy modeling contributes effectively to sustainable building design. Understanding which inputs warrant detailed attention supports more targeted and meaningful simulation workflows, enabling more accurate and impactful strategies for building energy efficiency and long-term environmental performance.
Ključne besede:building energy modeling, dynamic simulation, TRNSYS, envelope modeling parameters, building energy performance
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:07.06.2025
Leto izida:2025
Št. strani:17 str. [ǂarticle no.] ǂ5276
Številčenje:Vol. 17, iss. 12
PID:20.500.12556/DiRROS-22732 Novo okno
UDK:620.93
ISSN pri članku:2071-1050
DOI:10.3390/su17125276 Novo okno
COBISS.SI-ID:238718979 Novo okno
Avtorske pravice:© 2025 by the authors
Opomba:Nasl. z nasl. zaslona; Opis vira z dne 9. 6. 2025;
Datum objave v DiRROS:19.06.2025
Število ogledov:466
Število prenosov:298
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Sustainability
Skrajšan naslov:Sustainability
Založnik:MDPI
ISSN:2071-1050
COBISS.SI-ID:5324897 Novo okno

Licence

Licenca:CC BY 4.0, Creative Commons Priznanje avtorstva 4.0 Mednarodna
Povezava:http://creativecommons.org/licenses/by/4.0/deed.sl
Opis:To je standardna licenca Creative Commons, ki daje uporabnikom največ možnosti za nadaljnjo uporabo dela, pri čemer morajo navesti avtorja.

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:parametri modeliranja, energetski model, energetska učinkovitost stavbe, modeliranje ovojnice energetska učinkovitost stavbe, dinamična simulacija, energetsko modeliranje stavb