Digital repository of Slovenian research organisations

Show document
A+ | A- | Help | SLO | ENG

Title:Guidance document on multiplex real-time PCR methods : European Network of GMO Laboratories
Authors:ID Grohmann, Lutz (Author)
ID Barbante, Alessandra (Author)
ID Eriksson, Ronnie (Author)
ID Gatto, Francesco (Author)
ID Georgieva, Tzveta (Author)
ID Huber, Ingrid (Author)
ID Hulin, Julie (Author)
ID Köppel, René (Author)
ID Marchesi, Ugo (Author)
ID Marmin, Lucas (Author)
ID Mazzara, Marco (Author)
ID Narendja, Frank (Author)
ID Owen, Heather (Author)
ID Perri, Elena (Author)
ID Scholtens, Ingrid (Author)
ID Sovová, Tereza (Author)
ID Sowa, Slawomir (Author)
ID Štebih, Dejan (Author)
ID Weidner, Christopher (Author)
ID Zdeňková, Kamila (Author)
Files:URL URL - Source URL, visit https://op.europa.eu/publication/manifestation_identifier/PUB_KJNA30708ENN
 
URL URL - Source URL, visit https://data.europa.eu/doi/10.2760/243914
 
.pdf PDF - Presentation file, download (1,65 MB)
MD5: CD406107C42F36D239E62D0C1552182D
 
This document has even more files. Complete list of files is available below.
Language:English
Typology:2.12 - Final Research Report
Organization:Logo NIB - National Institute of Biology
Abstract:This document provides guidance for the development of new qualitative and quantitative multiplex real-time methods (mpPCR) and their implementation in a routine testing laboratory for food, feed and seeds. When implementing a mpPCR method, the laboratory should perform either an (in-house) validation or a verification of the method before its use. The various method performance parameters of the specific requirements for mpPCR are described and examples are given. Several different aspects have been considered, including the selection of the fluorophores, the master mix and the real-time PCR instrument used. The technical aspects are examined and recommendations are made on the choice of the detection and quantification strategy. Finally, a separate chapter is dedicated to troubleshooting (e.g. underperforming method, no or poor signal strength, cross-talk). In addition, a collection of existing mpPCR methods with emphasis on GMO detection is presented.
Publication status:Published
Publication version:Version of Record
Publication date:01.01.2023
Place of publishing:Luxembourg
Place of performance:Luxembourg
Publisher:Publications Office of the European Union
Year of publishing:2021
Year of performance:2021
Number of pages:1 spletni vir (1 datoteka PDF ([62] str.))
PID:20.500.12556/DiRROS-20262 New window
ISBN:978-92-76-37820-4
UDC:577
DOI:10.2760/243914 New window
COBISS.SI-ID:94024963 New window
Note:Soavtorji: Barbante A, Eriksson R, Gatto F, Georgieva T, Huber I, Hulin J, Köppel R, Marchesi U, Marmin L, Mazzara M, Narendja F, Owen H, Perri E, Scholtens I, Sovová T, Sowa S, Stebih D, Weidner C, Zdeňková K.; Nasl. z nasl. zaslona; Opis vira z dne 19. 1. 2022;
Publication date in DiRROS:02.09.2024
Views:9
Downloads:5
Metadata:XML RDF-CHPDL DC-XML DC-RDF
:
Copy citation
  
Share:Bookmark and Share


Hover the mouse pointer over a document title to show the abstract or click on the title to get all document metadata.

Document is financed by a project

Funder:EC - European Commission

Licences

License:CC BY 4.0, Creative Commons Attribution 4.0 International
Link:http://creativecommons.org/licenses/by/4.0/
Description:This is the standard Creative Commons license that gives others maximum freedom to do what they want with the work as long as they credit the author.

Files

Loading...

Back