Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:The effects of normobaric and hyperbaric oxygenation on MRI signal intensities in T1-weighted, T2-weighted and FLAIR images in human brain
Avtorji:ID Velej, Vida (Avtor)
ID Cankar, Ksenija (Avtor)
ID Vidmar, Jernej (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (1008,50 KB)
MD5: 4F5EE982D81CB81A22C4CEB8A891D16A
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo OI - Onkološki inštitut Ljubljana
Povzetek:Dissolved oxygen has known paramagnetic effects in magnetic resonance imaging (MRI). The aim ofthis study was to compare the effects of normobaric oxygenation (NBO) and hyperbaric oxygenation (HBO) on hu-man brain MRI signal intensities.Patients and methods. Baseline brain MRI was performed in 17 healthy subjects (mean age 27.8 ± 3.2). MRI wasrepeated after exposure to the NBO and HBO at different time points (0 min, 25 min, 50 min). Signal intensities in T1-weighted, T2-weighted images and fluid attenuated inversion recovery (FLAIR) signal intensities of several intracranialstructures were compared between NBO and HBO.Results. Increased T1-weighted signal intensities were observed in white and deep grey brain matter, cerebrospinalfluid (CSF), venous blood and vitreous body after exposure to NBO as well as to HBO compared to baseline (Dunnett’stest, p < 0.05) without significant differences between both protocols. There was also no significant difference in T2-weighted signal intensities between NBO and HBO. FLAIR signal intensities were increased only in the vitreous bodyafter NBO and HBO and FLAIR signal of caudate nucleus was decreased after NBO (Dunnett’s test, p < 0.05). Thestatistically significant differences in FLAIR signal intensities were found between NBO and HBO (paired t-test, p < 0.05)in most observed brain structures (paired t-test, p < 0.05).Conclusions. Our results show that NBO and HBO alters signal intensities T1-weighted and FLAIR images of humanbrain. The differences between NBO and HBO are most pronounced in FLAIR imaging.
Ključne besede:hyperbaric oxygen, normobaric oxygen, magnetic resonance, human brain
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.01.2023
Založnik:Association of Radiology and Oncology
Leto izida:2023
Št. strani:str. 317-324
Številčenje:Vol. 57, no. 3
Izvor:Ljubljana
PID:20.500.12556/DiRROS-19846 Novo okno
UDK:615.835:616.831
ISSN pri članku:1318-2099
DOI:10.2478/raon-2023-0043 Novo okno
COBISS.SI-ID:171909123 Novo okno
Avtorske pravice:by Authors
Datum objave v DiRROS:25.07.2024
Število ogledov:310
Število prenosov:125
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Radiology and oncology
Skrajšan naslov:Radiol. oncol.
Založnik:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 Novo okno

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:hiperbarični kisik, normobarični kisik, magnetna resonanca, človeški možgani


Nazaj