Digitalni repozitorij raziskovalnih organizacij Slovenije

Izpis gradiva
A+ | A- | Pomoč | SLO | ENG

Naslov:Breast size and dose to cardiac substructures in adjuvant three-dimensional conformal radiotherapy compared to tangential intensity modulated radiotherapy
Avtorji:ID Ratoša, Ivica (Avtor)
ID Jenko, Aljaša (Avtor)
ID Šljivić, Željko (Avtor)
ID Pirnat, Maja (Avtor)
ID Oblak, Irena (Avtor)
Datoteke:.pdf PDF - Predstavitvena datoteka, prenos (544,83 KB)
MD5: B96E3D256964CA2162478720C4BDC203
 
Jezik:Angleški jezik
Tipologija:1.01 - Izvirni znanstveni članek
Organizacija:Logo OI - Onkološki inštitut Ljubljana
Povzetek:The aim of the study was to quantify planned doses to the heart and specific cardiac substructures in free-breathing adjuvant three-dimensional radiation therapy (3D-CRT) and tangential intensity modulated radiotherapy (t-IMRT) for left-sided node-negative breast cancer, and to assess the differences in planned doses to organs at risk according to patients% individual anatomy, including breast volume. Patients and methods. In the study, the whole heart and cardiac substructures were delineated for 60 patients using cardiac atlas. For each patient, 3D-CRT and t-IMRT plans were generated. The prescribed dose was 42.72 Gy in 16 fractions. Patients were divided into groups with small, medium, and large clinical target volume (CTV). Calculated dose distributions were compared amongst the two techniques and the three different groups of CTV. Results. Mean absorbed dose to the whole heart (MWHD) (1.9 vs. 2.1 Gy, P < 0.005), left anterior descending coronary artery mean dose (8.2 vs. 8.4 Gy, P < 0.005) and left ventricle (LV) mean dose (3.0 vs. 3.2, P < 0.005) were all significantly lower with 3D-CRT technique compared to t-IMRT. Apical (8.5 vs. 9.0, P < 0.005) and anterior LV walls (5.0 vs. 5.4 Gy, P < 0.005) received the highest mean dose (Dmean). MWHD and LV-Dmean increased with increasing CTV size regardless of the technique. Low MWHD values (< 2.5 Gy) were achieved in 44 (73.3%) and 41 (68.3%) patients for 3D-CRT and t-IMRT techniques, correspondingly. Conclusions. Our study confirms a considerable range of the planned doses within the heart for adjuvant 3D-CRT or t-IMRT in node-negative breast cancer. We observed differences in heart dosimetric metrics between the three groups of CTV size, regardless of the radiotherapy planning technique.
Ključne besede:breast cancer, radiotherapy, 3D-CRT
Status publikacije:Objavljeno
Verzija publikacije:Objavljena publikacija
Datum objave:01.01.2020
Založnik:Association of Radiology and Oncology
Leto izida:2020
Št. strani:str. 470-479, X
Številčenje:Vol. 54, no. 4
Izvor:Ljubljana
PID:20.500.12556/DiRROS-19356 Novo okno
UDK:618.1
ISSN pri članku:1318-2099
DOI:10.2478/raon-2020-0050 Novo okno
COBISS.SI-ID:31459587 Novo okno
Avtorske pravice:by Authors
Datum objave v DiRROS:16.07.2024
Število ogledov:314
Število prenosov:158
Metapodatki:XML DC-XML DC-RDF
:
Kopiraj citat
  
Objavi na:Bookmark and Share


Postavite miškin kazalec na naslov za izpis povzetka. Klik na naslov izpiše podrobnosti ali sproži prenos.

Gradivo je del revije

Naslov:Radiology and oncology
Skrajšan naslov:Radiol. oncol.
Založnik:Slovenian Medical Society - Section of Radiology, Croatian Medical Association - Croatian Society of Radiology
ISSN:1318-2099
COBISS.SI-ID:32649472 Novo okno

Sekundarni jezik

Jezik:Slovenski jezik
Ključne besede:rak dojke, radioterapija, 3D-CRT


Nazaj