Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "avtor" (��trumbelj Tadeja) .

41 - 50 / 72
Na začetekNa prejšnjo stran12345678Na naslednjo stranNa konec
41.
Comparison of cycling high temperature corrosion at 650°C in the presence of NaCl of various austenitic stainless steels
Mirjam Bajt Leban, Maja Vončina, Tadeja Kosec, Robert Tisu, Matevž Barborič, Jože Medved, 2023, izvirni znanstveni članek

Povzetek: The high temperature corrosion at 650°C in the presence of NaCl at atmospheric pressure of AISI 304L, AISI 309, AISI 310S, AISI 314 and AISI 321 austenitic stainless steel was studied. The specimens were cyclically heated in the furnace and immersed in a 3.5% aqueous NaCl solution after cooling for 15 min. After each cycle, the change in mass of the samples was measured. The corroded samples were analysed by SEM /EDX, and the corrosion products were analysed by XRD. The chloride ions react with the steel surface to form porous and poorly adherent oxides and metal chlorides. After the mass increase during the first exposure cycles, spalling of the oxides occurred. The high temperature austenitic stainless steels (AISI 309, AISI 310S, AISI 314) showed less mass loss than conventional austenitic steels (AISI 304L). Surprisingly, the stainless steel AISI 321 showed a similar low weight loss after the cyclic test as AISI 309, but a detailed analysis of the exposed surfaces after the test showed a similar corrosion attack as for AISI 304. After the cyclic test at high temperature in the presence of NaCl, a higher concentration of Cr and Ni definitely improves the corrosion resistance under the present conditions, but a certain addition of Si is even more obvious.
Ključne besede: austenitic stainless steel, high temperature corrosion, NaCl, exhaust systems, open access
Objavljeno v DiRROS: 31.05.2023; Ogledov: 280; Prenosov: 177
.pdf Celotno besedilo (1,53 MB)
Gradivo ima več datotek! Več...

42.
Corrosion characterization and ion release in SLM-manufactured and wrought Ti6Al4V alloy in an oral environment
Mirjam Bajt Leban, Tadeja Kosec, Matjaž Finšgar, 2022, izvirni znanstveni članek

Povzetek: As-produced and heat-treated TiAlV samples were prepared by selective laser melting and compared to wrought samples of identical chemical composition. Microstructural, corrosion, and spectroscopic studies of additively manufactured samples in artificial saliva at 37 °C, with NaF and at pH 2.3 were as a novelty combined with metal ion release during 42 days immersion. In artificial saliva higher amount of ions was released on SLM specimen when compared to wrought alloy. The total amount of ions released from SLM specimen in AS containing NaF was 10-times higher than in AS, while in AS with lactic acid it was 100-times higher.
Ključne besede: Ti6Al4V, SLM, corrosion, ion release, XPS, ToF-SIMS
Objavljeno v DiRROS: 31.05.2023; Ogledov: 321; Prenosov: 261
.pdf Celotno besedilo (15,86 MB)
Gradivo ima več datotek! Več...

43.
Properties of the fluoroacrylate and methacryloxypropyl-trimethoxysilane applied to a layer of Cu2O on bronze as either single or multi-component coatings
Luka Škrlep, Tadeja Kosec, Matjaž Finšgar, Andrijana Sever Škapin, Erika Švara Fabjan, 2023, izvirni znanstveni članek

Povzetek: Various coatings have been developed and explored to protect bronze surfaces against the uncontrolled formation of different corrosion products when exposed to outdoor environments. In this research, the surfaces of artificially-formed oxidized bronze patinas (OB), consisting of Cu2O, were covered with either a single-component (fluoroacrylate, FA or methacryloxypropyl-trimethoxysilane, MS) or multi-component (a mixture of FA and MS, FA-MS) fluoropolymer coating and investigated. Variations in the concentration of each component in the coating were studied. Electrochemical tests were performed to determine the corrosion protection efficiency, followed by detailed surface analyses of the OBs, both uncoated and covered with single and multi-component coatings. A variety of investigative methods were used, including focused ion beam scanning electron microscopy (FIB-SEM), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The coating made from a combination of FA and MS resulted in a very high protection efficiency. Despite the increased hydrophilicity of the single MS component, however, it was shown to efficiently protect the oxidized bronze surface. The FA-MS systems showed high hydrophobicity, but no improvement was measured in the efficiency of the corrosion protection when it was compared to the coating that contained 10% MS. According to XPS and ToF-SIMS imaging, the FA component of the FA-MS coating was not present only on the uppermost surface of the coating but throughout the whole coating, which could affect its corrosion protection efficiency.
Ključne besede: bronze, Cu2O layer on bronze, fluoropolymer coating, protection efficiency, surface spectroscopy
Objavljeno v DiRROS: 30.05.2023; Ogledov: 346; Prenosov: 183
.pdf Celotno besedilo (8,49 MB)
Gradivo ima več datotek! Več...

44.
Characterization of steel corrosion processes in various blended cements by means of coupled multi-electrode arrays
Miha Hren, Tadeja Kosec, Andraž Legat, 2023, izvirni znanstveni članek

Povzetek: Supplementary cementitious materials can affect the porosity of concrete, pore solution pH and chloride binding, all of which influence the type and magnitude of corrosion damage. Advanced corrosion monitoring techniques are needed to follow the development of corrosion on steel embedded in concrete across space and over time. In this study, coupled multi-electrode arrays (CMEAs) were used to characterise corrosion processes in OPC and three blended cements. Cyclic wetting with chlorides was undertaken to initiate corrosion. The results showed three distinct types of corrosion: localised corrosion (CEM I), localised corrosion that expanded over time (CEM II), and a combination of localised and general corrosion (CEM III and CEM IV). Cathodic locations were also monitored successfully, and the corrosion behaviour was related to total porosity and pH of the pore solution. MicroCT was used to quantify the volume of corroded material, which agreed well with results calculated from the CMEA measurements.
Ključne besede: blended cements, coupled multi-electrode array, corrosion of steel in concrete, supplementary cementitious materials, open access
Objavljeno v DiRROS: 29.05.2023; Ogledov: 284; Prenosov: 177
.pdf Celotno besedilo (12,61 MB)
Gradivo ima več datotek! Več...

45.
Differences between 3-D printed and traditionally milled CoCr dental alloy from casted block in oral environment
Mirjam Bajt Leban, Matej Kurnik, Igor Kopač, Matic Klug Jovičević, Bojan Podgornik, Tadeja Kosec, 2023, izvirni znanstveni članek

Povzetek: The aim of this study was to compare corrosion resistance and ion release in CoCr dental alloys with identical chemical compositions produced using different technologies (SLM – selective laser melting and milling from cast blocks) and heat treatment (SLM parts only). The corrosion properties were tested in artificial saliva, artificial saliva with fluoride ions, and artificial saliva with added lactic acid to simulate inflammations. The study included electrochemical tests, microstructural investigation and ion release tests in the three different environments for a total of 42 days. The best performance of CoCr as a result of potentiodynamic polarization was observed in the artificial saliva with added lactic acid, which is in contradiction with the highest ion release measured from all the materials tested and electrochemical impedance spectroscopy that showed a deterioration of the passive layer in an acidic environment. Microstructural investigation revealed that different phases precipitated by heat treatment trigger increased release of Mo and W ions. The printing method does not raise critically ion release from CoCr alloy, while the state of the surface greatly impacts the extent of the ion release. This study demonstrates the importance of an interdisciplinary approach to the study of corrosion and biocompatibility in dental alloys.
Ključne besede: CoCr dental alloy, selective laser melting, corrosion, ion release, artificial saliva
Objavljeno v DiRROS: 29.05.2023; Ogledov: 344; Prenosov: 290
.pdf Celotno besedilo (9,28 MB)
Gradivo ima več datotek! Več...

46.
Influence of the deep cryogenic treatment on AISI 52100 and AISI D3 steelʼs corrosion resistance
Patricia Jovičević Klug, Tjaša Kranjec, Matic Klug Jovičević, Tadeja Kosec, Bojan Podgornik, 2021, izvirni znanstveni članek

Povzetek: The effect of deep cryogenic treatment (DCT) on corrosion resistance of steels AISI 52100 and AISI D3 is investigated and compared with conventional heat-treated counterparts. DCTʼs influence on microstructural changes is subsequently correlated to the corrosion resistance. DCT is confirmed to reduce the formation of corrosion products on steelsʼ surface, retard the corrosion products development and propagation. DCT reduces surface cracking, which is considered to be related to modified residual stress state of the material. DCTʼs influence on each steel results from the altered microstructure and alloying element concentration that depends on steel matrix and type. This study presents DCT as an effective method for corrosion resistance alteration of steels.
Ključne besede: steel, deep cryogenic treatment, corrosion, Raman, open access
Objavljeno v DiRROS: 19.05.2023; Ogledov: 312; Prenosov: 226
.pdf Celotno besedilo (3,13 MB)
Gradivo ima več datotek! Več...

47.
Effect of laser texturing pattern on Ti6Al4Vtribocorrosion in a physiological solution
Marjetka Conradi, Tadeja Kosec, Bojan Podgornik, Aleksandra Kocijan, Janez Kovač, Damjan Klobčar, 2022, izvirni znanstveni članek

Povzetek: Laser texturing is a process that alters a material’s surface properties by modifying its morphology, which can improve properties like adherence, wettability, thermal and electrical conductivity and friction. Here, the effect of laser texturing was studied on an alpha-beta titanium alloy (Ti6Al4V) biomedical material. Two types of patterned surfaces, cross-hatch with varying scan-line separations, Dx = 100, 180 and 280 μm and dimples of 200 μm size, were prepared on the surface of alpha-beta titanium alloy by laser technology. Prepared samples were characterised for their surface properties, such as corrosion, wear-induced corrosion, friction and wettability. Electrochemical and tribocorrosion properties in a physiological solution were studied on the samples with different texture densities of cross-hatch pattern and dimples and compared to the as-received alpha-beta titanium alloy surface. Corrosion rate decreased for laser-textured samples, especially for cross-hatch texture (down to 1 μm/year for Dx = 180 μm) when compared to the as-received alpha-beta titanium alloy surface due to the changed laser-induced surface film and wetting properties. Friction coefficient slightly decreased for all laser-textured surfaces, most noticeably for cross-hatch patterns, from 0.38 (as-received) down to 0.34 (Dx = 180 and 280 μm). The main contribution to total wear in physiological solution increased due to the mechanical wear, which is governed by the removal of the surface oxide layer induced by laser texturing.
Ključne besede: TiAIV, laser texturing, tribocorrosion, open access
Objavljeno v DiRROS: 17.05.2023; Ogledov: 294; Prenosov: 120
.pdf Celotno besedilo (2,19 MB)
Gradivo ima več datotek! Več...

48.
An electrochemical and spectroscopic study of surfaces on bronze sculptures exposed to urban environment
Dajana Mikić, Helena Otmačić Ćurković, Tadeja Kosec, Neven Peko, 2021, izvirni znanstveni članek

Povzetek: Polluted urban environment enhances dissolution of patina and underlying bronze material of recent and historical bronze sculptures exposed outdoors. In this work, two bronze statues, situated in one of the most polluted Croatian cities, were examined in order to characterize composition of patina and its electrochemical stability. The composition of patina on several positions on each sculpture was determined by EDS, Raman spectroscopy, and FTIR measurements. Electrochemical impedance spectroscopy measurements were conducted in order to evaluate the corrosion stability of both patina and underlying bronze. Results obtained in this work show that the two examined bronze sculptures were covered with patina layer that was mainly composed of copper sulfides and sulphates, which is in accordance with the high concentrations of H2S and SO2 in the atmosphere. However, the variations in the appearance of FTIR and Raman spectra revealed that the amount of each species differed from spot to spot, as well as the fact that other compounds, such as carbonates, were present at some areas. This difference in patina composition was reflected in electrochemical behavior as observed by electrochemical impedance spectroscopy.
Ključne besede: bronze, corrosion, spectroscopy, FTIR, Raman, EIS, open access
Objavljeno v DiRROS: 16.05.2023; Ogledov: 297; Prenosov: 174
.pdf Celotno besedilo (4,82 MB)
Gradivo ima več datotek! Več...

49.
Integrating physical activity in mathematics lessons : a pilot study
Erika Černigoj, Tadeja Volmut, 2021, izvirni znanstveni članek

Ključne besede: children, sixth grade, moderate to vigorous intensity, accelerometer
Objavljeno v DiRROS: 02.03.2023; Ogledov: 321; Prenosov: 167
.pdf Celotno besedilo (384,27 KB)
Gradivo ima več datotek! Več...

50.
Psevdoprogres : terapevtska zagata v imunoterapiji
Tadeja Skok, Nina Boc, 2023, objavljeni znanstveni prispevek na konferenci

Povzetek: Sistemsko zdravljenje z imunoterapijo je v klinično prakso prineslo nove, atipične vzorce odgovorov solidnih tumorjev na zdravljenje ter tako vplivalo na radiološko oceno odgovora na terapijo. Psevdoprogres je opredeljen kot začetno povečanje bremena bolezni s kasnejšim zmanjšanjem. Pri hiperprogresu pride do hitrega povečanja tumorskega bremena, pogosto v povezavi s kliničnim poslabšanjem. Trenutno najbolj uporabljeni iRECIST kriteriji za oceno učinka imunoterapije so bili objavljeni leta 2017 ter temeljijo na osnovi kriterijev RECIST 1.1. Najpomembnejša razlika med osnovnimi RECIST kriteriji ter iRECIST kriteriji je uvedba dodatnih kontrolnih preiskav za potrditev napredovanja bolezni.
Ključne besede: imunoterapija, onkologija, onkološko zdravljenje
Objavljeno v DiRROS: 16.02.2023; Ogledov: 494; Prenosov: 226
.pdf Celotno besedilo (16,12 MB)
Gradivo ima več datotek! Več...

Iskanje izvedeno v 0.3 sek.
Na vrh