Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "ključne besede" (archwires) .

1 - 3 / 3
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
A critical appraisal of the use and properties of nickel–titanium dental alloys
Petra Močnik, Tadeja Kosec, 2021, pregledni znanstveni članek

Povzetek: Nickel–titanium (NiTi) archwires are used in dentistry for orthodontic treatment. NiTi alloys have favourable mechanical characteristics, such as superelasticity and shape memory, and are also known as a corrosion-resistant alloy. In specific cases, an archwire could be attacked by certain types of corrosion or wear degradation, which can cause the leaching of metal ions and a hypersensitive response due to increased concentrations of Ni in the human body. A systematic search of the literature retrieved 102 relevant studies. The review paper focuses on three main fields: (i) electrochemical properties of NiTi wires and the effect of different environments on the properties of NiTi wires (fluoride and low pH); (ii) tribocorrosion, a combination of chemical and mechanical wear of the material, and (iii) the biocompatibility of NiTi alloy and its subsequent effect on the human body. The review showed that corrosion properties are affected by microstructure, pH of saliva and the presence of fluorides. A high variation in published results should be, therefore, interpreted with care. The release of nickel ions was assessed using the same unit, showing that the vast majority of metal ions were released in the first few days of exposure, then a stable, steady state was reached. In tribocorrosion studies, the increased concentrations of Ni ions were reported.
Ključne besede: NiTi alloy, archwires, corrosion, NI ion release
Objavljeno v DiRROS: 23.02.2024; Ogledov: 203; Prenosov: 66
.pdf Celotno besedilo (2,18 MB)
Gradivo ima več datotek! Več...

2.
Tribocorrosive study of new and in vivo exposed nickel titanium and stainless steel orthodontic archwires
Tadeja Kosec, Petra Močnik, Uroš Mezeg, Andraž Legat, Maja Ovsenik, Monika Jenko, John T. Grant, Jasmina Primožič, 2020, izvirni znanstveni članek

Povzetek: The surface, corrosion and wear properties of new and in vivo exposed nickel titanium (NiTi) and stainless steel (SS) archwires used in orthodontic treatment were investigated. Electrochemical and tribo-electrochemical tests in artificial saliva were performed in order to define corrosion properties and to estimate wear rate of new and in vivo exposed NiTi and SS archwires. The surface chemical analysis of the passive film on the NiTi and SS archwires before and after tribocorrosion tests was performed by Auger Electron Spectroscopy (AES). In vivo exposed NiTi and SS archwires had better electrochemical properties than new archwires due to the protective nature of oral deposits. Total wear and coefficients of friction were higher among in vivo exposed archwires and higher in NiTi archwires in comparison to SS archwires. The estimated thickness of the TiO2 passive film on as-received NiTi is 8 nm, while the passive Cr2O3 film on as-received SS is just 1–2 nm. On in vivo exposed NiTi archwire, a 60–80 nm thick organic film/dental plaque was observed, and on SS, it was thinner, at about 60 nm. This research shows the importance of combining AES with electrochemical testing, to characterize tribocorrosive properties of NiTi and SS orthodontic archwires.
Ključne besede: archwires, NiTi, stainless steel, wear
Objavljeno v DiRROS: 24.08.2023; Ogledov: 272; Prenosov: 115
.pdf Celotno besedilo (2,18 MB)
Gradivo ima več datotek! Več...

3.
Tribocorrosion susceptibility and mechanical characteristics of as-received and long-term in-vivo aged nickel-titanium and stainless-steel archwires
Jasmina Primožič, Miha Hren, Uroš Mezeg, Andraž Legat, 2022, izvirni znanstveni članek

Povzetek: To evaluate the effect of long-term in-vivo aging on orthodontic archwires, we aimed to assess the triboelectrochemical and mechanical characteristics of as-received and in-vivo aged nickel-titanium (NiTi) and stainless-steel (SS) orthodontic archwires. Four consecutive tribocorrosion cycles on six NiTi and six SS archwires, as-received and in-vivo aged, were performed on a reciprocal tribometer. Electrochemical noise and friction coefficient measurements, three-dimensional surface profiling, and hardness measurements were performed. Repassivation times of as-received archwires were longer than of the in-vivo aged; however, were shorter for NiTi. Friction coefficients were higher for NiTi than for SS archwires. Sudden major current drops concomitant with inverse potential shifts and friction coefficients’ fluctuations, were seen for as-received (last cycle) and in-vivo aged (last three cycles) NiTi archwires. More pronounced tribocorrosion damage was observed on in-vivo aged NiTi than on other archwires. Hardness was generally higher inside the wear track of archwires. Long-term in-vivo exposure decreases the corrosion susceptibility of archwires, more evidently for the NiTi ones. Sudden major fluctuations in electrochemical current, potential, and friction coefficient detected for NiTi archwires, might be related to localized residual parts of the oxide layer persisting due to increased surface roughness or to phase transformations of the alloy’s crystal structure.
Ključne besede: tribocorrosion, orthodontic archwires, electrochemical noise, open access
Objavljeno v DiRROS: 26.04.2023; Ogledov: 367; Prenosov: 146
.pdf Celotno besedilo (2,52 MB)
Gradivo ima več datotek! Več...

Iskanje izvedeno v 0.05 sek.
Na vrh