1. |
2. NutriGreen image dataset : a collection of annotated nutrition, organic, and vegan food productsJan Drole, Igor Pravst, Tome Eftimov, Barbara Koroušić-Seljak, 2024, izvirni znanstveni članek Povzetek: In this research, we introduce the NutriGreen dataset, which is a collection of images representing branded food products aimed for training segmentation models for detecting various labels on food packaging. Each image in the dataset comes with three distinct labels: one indicating its nutritional quality using the Nutri-Score, another denoting whether it is vegan or vegetarian origin with the V-label, and a third displaying the EU organic certification (BIO) logo. Objavljeno v DiRROS: 23.04.2024; Ogledov: 63; Prenosov: 27 Celotno besedilo (2,84 MB) |
3. Segmentation of hepatic vessels from MRI images for planning of electroporation-based treatments in the liverMarija Marčan, Denis Pavliha, Maja Marolt-Mušič, Igor Fučkan, Ratko Magjarević, Damijan Miklavčič, 2014, izvirni znanstveni članek Ključne besede: electrochemotherapy, non-thermal irreversible electroporation, treatment planning, hepatic vessel segmentation, non-invasive tumor treatments, MRI of liver Objavljeno v DiRROS: 16.04.2024; Ogledov: 94; Prenosov: 49 Celotno besedilo (945,02 KB) Gradivo ima več datotek! Več... |
4. Depth of SCUBA diving affects cardiac autonomic nervous systemMarina Vulić, Branislav Milovanovic, Ante Obad, Duška Glavaš, Igor Glavičič, Damir Zubac, Maja Valic, Zoran Valić, 2024, pregledni znanstveni članek Povzetek: The present study investigated the influence of SCUBA dives with compressed air at depths of 10 and 20 m on ECG-derived HRV parameters in apparently healthy individuals. We hypothesized that cardiac sympathetic activity (measured by HRV parameters) adapts proportionally to diving depth, and that both time- and frequency-domain parameters are sensitive enough to track changes in cardiac ANS function during diving activities and subsequently during the recovery period. Eleven healthy middle-aged recreational divers (nine men and two women, age 43 ± 8, all nonsmokers) volunteered to participate in the present study. The participants (all open-circuit divers) were equipped with dry suits and ECG Holter devices and were later randomly assigned to dive pairs and depths (10 m vs. 20 m), and each participant served as his or her own control. No interaction effects (diving depth x time epoch) were found for the most commonly used HRV markers. More precisely, in response to two different diving protocols, a significant post hoc effect of time was observed for HR and SDNN, as these parameters transiently decreased during the dives and returned to baseline after ascent (p < 0.001). The ULF, VLF (p < 0.003), TP, and LF parameters decreased significantly during the dives, while HF significantly increased (p < 0.003). SCUBA diving apparently challenges the cardiac ANS, even in healthy individuals. The observed changes reveal possible underwater methods of influencing the parasympathetic activity of the heart depending on the depth of the dive. These results identify autonomic nervous system markers to track the cardiovascular risk related to diving and point to the possibility of tracking cardiovascular system benefits during underwater activities in selected patients Ključne besede: autonomic nervous system, diving, parasympathicus, cardiovascular risk Objavljeno v DiRROS: 09.04.2024; Ogledov: 82; Prenosov: 38 Celotno besedilo (456,62 KB) Gradivo ima več datotek! Več... |
5. |
6. Human tooth pulp anatomy visualization by 3D magnetic resonance microscopyDušan Šušterčič, Igor Serša, 2012, izvirni znanstveni članek Povzetek: Background. Precise assessment of dental pulp anatomy is of an extreme importance for a successful endodontic treatment. As standard radiographs of teeth provide very limited information on dental pulp anatomy, more capable methods are highly appreciated. One of these is 3D magnetic resonance (MR) microscopy of which diagnostic capabilities in terms of a better dental pulp anatomy assessment were evaluated in the study. Materials and methods. Twenty extracted human teeth were scanned on a 2.35 T MRI system for MR microscopy using the 3D spin-echo method that enabled image acquisition with isotropic resolution of 100 m. The 3D images were then post processed by ImageJ program(NIH) to obtain advanced volume rendered views of dental pulps. Results. MR microscopy at 2.35 T provided accurate data on dental pulp anatomyin vitro. The data were presented as a sequence of thin 2D slices through the pulp in various orientations or as volume rendered 3D images reconstructed form arbitrary view-points. Sequential 2D images enabled only anapproximate assessment of the pulp, while volume rendered 3D images were more precise in visualization of pulp anatomy and clearly showed pulp diverticles, number of pulp canals and root canal anastomosis. Conclusions. This in vitro study demonstrated that MR microscopy could provide very accurate 3D visualization of dental pulp anatomy. A possible future application of the method in vivo may be of a great importance for the endodontic treatment. Objavljeno v DiRROS: 21.03.2024; Ogledov: 105; Prenosov: 27 Celotno besedilo (1004,44 KB) |
7. Meshless simulation of a macrosegregation benchmark considering the solid motionViktor Govže, Igor Vušanović, Božidar Šarler, 2023, objavljeni znanstveni prispevek na konferenci Povzetek: We have extended the existing two-dimensional rigid solid phase benchmark for binary substance with the solid phase motion in the present paper. Incompressible laminar Newtonian flow is assumed, and a standard mixture formulation is used for the mass, momentum, energy, and solute transport. A coherency solid motion model accounts for the free-floating grains, assuming that the solid velocity is proportional to the mixture velocity and the liquid fraction. The lever rule is used to describe the mass fractions of the phases. A two-dimensional benchmark is solved using the semi-implicit meshless diffuse approximate method with an adaptive subdomain upwinding strategy. The results of the meshless method are compared to the finite volume method results with a reasonable agreement. The new benchmark results show that the solid motion has an essential effect on the macrosegregation pattern. Ključne besede: solidification, meshless methods, grain motion, benchmarks Objavljeno v DiRROS: 21.03.2024; Ogledov: 122; Prenosov: 66 Celotno besedilo (1,11 MB) Gradivo ima več datotek! Več... |
8. CT colonography in detection of colorectal carcinomaAmela Sofić, Šerif Beslić, Igor Kocijančič, Nedžad Šehović, 2010, izvirni znanstveni članek Povzetek: Background. Diagnostic methods used in screening and detectingand 2 lipomas,and 2 lipomas, among tumours there were 55 adenocarcinomas and 1 lymphoma. Results showed CT colonography among tumours there were 55 adenocarcinomas and 1 lymphoma. Results showed CTsensitivity to polyps to be 89.7%, barium enema 48.7%, and colonoscopy 94.9%. Sensitivity to tumours of CT colonography colonography colorectal CT barium enema followed by colonoscopy wereand colonoscopy was 100% and of barium enema 94.6%. Specificities and PPV were 100% in all procedures. The performed. After thesensitivity to polyps to be 89.7%, barium enema 48.7%, andcomfort assessment showed CT colonography as the far most comfortable out of three procedures. colonoscopy 94.9%. Sensitivity to tumours of CT colonography procedures a comfort assessment was done in all colonography. The aim of thisand colonoscopy was 100% and of barium enema 94.6%. Specificities and PPV were 100% in all procedures. The study was to establish diagnostic accuracy andpatients. Diagnostic positive comfort assessment showed CT colonography as the far most comfortable out of three procedures. results were verified by the pato-histological examination. Sensitivity, specificity, positive comfort of CT colonography compared carcinoma are digitorectal examination,topredicative value (PPV) and negative predicative value (NPV) were calculated for each procedure. Ključne besede: CT colonography, barium enema, colonoscopy, colorectal polyp, colorectal carcinoma Objavljeno v DiRROS: 18.03.2024; Ogledov: 92; Prenosov: 30 Celotno besedilo (933,29 KB) |
9. Study of radiation induced changes of phosphorus metabolism in mice by ▫$^{31}P$▫ NMR spectroscopyIgor Serša, Simona Kranjc Brezar, Gregor Serša, Alenka Nemec Svete, Bojan Ložar, Ana Sepe, Jernej Vidmar, Marjeta Šentjurc, 2010, izvirni znanstveni članek Objavljeno v DiRROS: 15.03.2024; Ogledov: 99; Prenosov: 34 Celotno besedilo (699,32 KB) |
10. |