Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "ključne besede" (micro-CT) .

1 - 8 / 8
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Characterization of micro-threaded stem taper surface of cementless hip endoprostheses
Drago Dolinar, Boštjan Kocjančič, Klemen Avsec, Barbara Šetina, Aleksandra Kocijan, Matjaž Godec, Marko Sedlaček, Mojca Debeljak, John T. Grant, Timon Zupanc, Monika Jenko, 2024, izvirni znanstveni članek

Povzetek: We investigated micro-threaded stem taper surface and its impact on premature failures, aseptic loosening, and infection in cementless hip endoprostheses. Our study focused on the fretting, and crevice corrosion of micro-threaded tapers, as well as the characterization of the microstructure and surface properties of two new and three retrieved Zweymüller stem tapers. The retrieved samples were selected and examined based on the head–stem taper interface being the sole source of modularity with a metallic component, specifically between the Ti alloy taper stem and the ceramic head. To determine the surface chemistry and microstructures of both new and retrieved hip endoprostheses stem taper titanium alloy, scanning -electron microscopy (SEM) was employed for morphological and microstructural analyses. Energy dispersive spectroscopy (EDS) was utilized for characterizing chemical element distribution, and electron backscattered diffraction (EBSD) was used for phase analysis. The roughness of the micro-threated stem tapers from different manufacturers was investigated using an optical profilometer, with standard roughness parameters Ra (average surface roughness) and Rz (mean peak to valley height of the roughness profile) being measured. Electrochemical studies revealed no fretting corrosion in retrieved stem tapers with ceramic heads. Consequently, three retrieved tapers and two new ones for comparison underwent potentiodynamic measurements in Hank’s solution to determine the corrosion rate of new and retrieved stem taper surfaces. The results showed a low corrosion rate for both new and prematurely failed retrieved samples due to aseptic loosening. However, the corrosion rate was higher in infected and low-grade infected tapers. In conclusion, our study suggests that using ceramic heads reduces taper corrosion and subsequently decreases the incidence of premature failures in total hip arthroplasty.
Ključne besede: total hip arthroplasty, stem micro-threaded taper, taper surface morphology, microstructure, corrosion, Ti implant alloy
Objavljeno v DiRROS: 06.06.2024; Ogledov: 61; Prenosov: 49
.pdf Celotno besedilo (8,47 MB)
Gradivo ima več datotek! Več...

2.
A numerical study of gas focused non-Newtonian micro-jets
Rizwan Zahoor, Saša Bajt, Božidar Šarler, 2024, izvirni znanstveni članek

Ključne besede: serial crystallography, micro jets, multiphase flow, fluid rheology, non-Newtonian fluid, flow focusing
Objavljeno v DiRROS: 28.02.2024; Ogledov: 224; Prenosov: 100
.pdf Celotno besedilo (11,78 MB)
Gradivo ima več datotek! Več...

3.
An experimental study of liquid micro-jets produced with a gas dynamic virtual nozzle under the influence of an electric field
Bor Zupan, Gisel Esperanza Peña-Murillo, Rizwan Zahoor, Jurij Gregorc, Božidar Šarler, Juraj Knoška, Alfonso M. Gañán-Calvo, Henry N. Chapman, Saša Bajt, 2023, izvirni znanstveni članek

Povzetek: The results of an experimental study of micro-jets produced with a gas dynamic virtual nozzle (GDVN) under the influence of an electric field are provided and discussed for the first time. The experimental study is performed with a 50% volume mixture of water and ethanol, and nitrogen focusing gas. The liquid sample and gas Reynolds numbers range from 0.09–5.4 and 0–190, respectively. The external electrode was positioned 400–500 μm downstream of the nozzle tip and an effect of electric potential between the electrode and the sample liquid from 0–7 kV was investigated. The jetting parametric space is examined as a function of operating gas and liquid flow rates, outlet chamber pressure, and an external electric field. The experimentally observed jet diameter, length and velocity ranged from 1–25 μm, 50–500 μm and 0.5–10 m/s, respectively. The jetting shape snapshots were processed automatically using purposely developed computer vision software. The velocity of the jet was calculated from the measured jet diameter and the sample flow rate. It is found that micro-jets accelerate in the direction of the applied electric field in the downstream direction at a constant acceleration as opposed to the standard GDVNs. New jetting modes were observed, where either the focusing gas or the electric forces dominate, encouraging further theoretical and numerical studies towards optimized system design. The study shows the potential to unlock a new generation of low background sample delivery for serial diffraction measurements of weakly scattering objects.
Ključne besede: micro jet, electric field, experimental study, flow focusing, Taylor cone, gas dynamic virtual nozzles
Objavljeno v DiRROS: 07.02.2024; Ogledov: 355; Prenosov: 124
.pdf Celotno besedilo (1,94 MB)
Gradivo ima več datotek! Več...

4.
5.
Characterization of fly ash alkali activated foams obtained using sodium perborate monohydrate as a foaming agent at room and elevated temperatures
Lidija Korat, Vilma Ducman, 2020, izvirni znanstveni članek

Povzetek: Alkali activated foams have been extensively studied in recent years, due to their high performance and low environmental footprint compared to foams produced via other methods. Three types of fly ash differing in chemical and mineralogical composition and specific surface were used to synthesize alkali activated foams. Sodium perborate monohydrate was added as a foaming agent and sodium dodecyl sulphate as a stabilizing agent. Foams were characterized at room temperature and after exposure to an elevated temperature (1,000 °C). Densities from 1.2 down to 0.3 g/cm 3 were obtained, depending on the type of fly ash and quantity of foaming agent added. Correspondingly, compressive strength ranged from 1 to 6 MPa. Comparing all three fly ashes the most favorable results, in terms of density and corresponding compressive strength, were achieved from the fly ash with the highest amounts of SiO 2 and Al2 O 3 , as well as the highest amorphous phase content i.e., RI fly ash. Furthermore, after firing to 1,000 °C, the density of samples prepared using fly ash RI remained approximately the same, while the compressive strength increased on average by 50%. In the other two types of fly ash the density increased slightly after firing, due to significant shrinkage, and compressive strength increased by as much as 800%. X-ray powder diffraction analysis confirmed the occurrence of a crystallization process after firing to 1,000 ° C, which resulted in newly formed crystal phases, including nepheline, sodalite, tridymite, and gehlenite.
Ključne besede: foamed alkali activated materials, geopolymers, properties, micro-CT
Objavljeno v DiRROS: 22.08.2023; Ogledov: 323; Prenosov: 207
.pdf Celotno besedilo (7,94 MB)
Gradivo ima več datotek! Več...

6.
Suspension of discrete microscopic oscillators as a model of an ultrasonic metafluid
Aljaž Draškovič-Bračun, Tilen Potisk, Matej Praprotnik, Daniel Svenšek, 2022, izvirni znanstveni članek

Ključne besede: metamaterials, acoustics, micro-oscillators
Objavljeno v DiRROS: 29.11.2022; Ogledov: 493; Prenosov: 235
.pdf Celotno besedilo (2,55 MB)
Gradivo ima več datotek! Več...

7.
8.
Iskanje izvedeno v 0.25 sek.
Na vrh