Digital repository of Slovenian research organisations

Search the repository
A+ | A- | Help | SLO | ENG

Query: search in
search in
search in
search in

Options:
  Reset


Query: "author" (%EF%BF%BD%EF%BF%BDifrer Robert) .

1 - 10 / 216
First pagePrevious page12345678910Next pageLast page
1.
2.
Prepoznavanje ogroženosti za nastanek raka dojk na mamografskih slikah
Žan Klaneček, Andrej Studen, Katja Jarm, Mateja Krajc, Miloš Vrhovec, Robert Jeraj, 2024, published professional conference contribution

Abstract: Za prehod s populacijskega na personalizirano presejanje za raka dojk je v prvi vrsti potrebno natančno prepoznavanje ogroženosti za razvoj raka dojk. Standardni modeli, ki temeljijo na klasičnih značilkah, niso najbolj zanesljivi. Z razvojem umetne inteligence, predvsem na področju globokega učenja, se je izkazalo, da modeli, ki so naučeni na mamografskih slikah, dosegajo signifikantno boljše rezultate pri napovedovanju ogroženosti. Trenutno je najboljši model za napovedovanje ogroženosti MIRAI, ki je bil uspešno validiran na različnih populacijah. A vendar so rezultati še daleč od popolnih in možnosti za izboljšave je ogromno, predvsem na področju razširitve uporabnosti modela za različne proizvajalce mamografskih aparatov, vključevanja longitudinalnih sprememb in uporabe segmentiranih slik dojke.
Keywords: obvladovanje raka, presejalni programi, rak dojk, mamografija
Published in DiRROS: 06.06.2024; Views: 57; Downloads: 16
.pdf Full text (85,28 KB)

3.
Echocardiography and cardiac biomarkers in patients with non-small cell lung cancer treated with platinum-based chemotherapy
Daniel Omersa, Tanja Čufer, Robert Marčun, Mitja Lainščak, 2017, original scientific article

Abstract: Background. Non-small cell lung cancer (NSCLC) is the most common type of lung cancer and remains an important cause of cancer death worldwide. Platinum-based chemotherapy (PBC) for NSCLC can modify outcome while the risk of cardiotoxicity remains poorly researched. We aimed to evaluate the incidence and severity of cardiac injury during PBC in patients with NSCLC and to identify patients at risk. Methods. This was a single-centre, prospective, observational study of patients with early and advanced stage NSCLC referred for PBC. In addition to standard care, patients were examined and evaluated for cardiotoxicity before the first dose (visit 1), at the last dose (visit 2) and 6 months after the last dose of PBC (visit 3). Cardiotoxicity (at visit 2 and 3) was defined as increase in the ultrasensitive troponin T, N-terminal pro-B type natriuretic peptide or decrease in left ventricular ejection fraction (LVEF). Results. Overall, 41 patients (mean age 61 +/- 9; 54% men; 68% advanced lung cancer) were included. The median number of PBC cycles was 4. During the study period, there were no incidents of heart failure, and 3 deaths caused by tumour progression were recorded. The mean values of biomarkers and LVEF did not change significantly (p > 0.20). However, 10 (25%) had cardiotoxicity which was independently associated with a history of ischemic heart disease (p = 0.026). Conclusions. In NSCLC, cardiac assessment and lifestyle modifications may be pursued in patients with a history of cardiac disease and in patients with longer life expectancy.
Published in DiRROS: 10.05.2024; Views: 119; Downloads: 60
.pdf Full text (437,07 KB)
This document has many files! More...

4.
Virtual modelling of novel applicator prototypes for cervical cancer brachytherapy
Primož Petrič, Robert Hudej, Noora Al-Hammadi, Barbara Šegedin, 2016, original scientific article

Abstract: Standard applicators for cervical cancer Brachytherapy (BT) do not always achieve acceptable balance between target volume and normal tissue irradiation. We aimed to develop an innovative method of Targetvolume Density Mapping (TDM) for modelling of novel applicator prototypes with optimal coverage characteristics. Patients and methods. Development of Contour-Analysis Tool 2 (CAT-2) software for TDM generation was the core priority of our task group. Main requests regarding software functionalities were formulated and guided the coding process. Software validation and accuracy check was performed using phantom objects. Concepts and terms for standardized workflow of TDM post-processing and applicator development were introduced. Results. CAT-2 enables applicator-based co-registration of Digital Imaging and Communications in Medicine (DICOM) structures from a sample of cases, generating a TDM with pooled contours in applicator-eye-view. Each TDM voxel is assigned a value, corresponding to the number of target contours encompassing that voxel. Values are converted to grey levels and transformed to DICOM image, which is transported to the treatment planning system. Iso-density contours (IDC) are generated as lines, connecting voxels with same grey levels. Residual Volume at Risk (RVR) is created for each IDC as potential volume that could contain organs at risk. Finally, standard and prototype applicators are applied on the TDM and virtual dose planning is performed. Dose volume histogram (DVH) parameters are recorded for individual IDC and RVR delineations and characteristic curves generated. Optimal applicator configuration is determined in an iterative manner based on comparison of characteristic curves, virtual implant complexities and isodose distributions. Conclusions. Using the TDM approach, virtual applicator prototypes capable of conformal coverage of any target volume, can be modelled. Further systematic assessment, including studies on clinical feasibility, safety and effectiveness are needed before routine use of novel prototypes can be considered.
Keywords: cervical cancer, brachytherapy, applicators, virtual modelling
Published in DiRROS: 09.05.2024; Views: 123; Downloads: 63
.pdf Full text (671,88 KB)

5.
6.
MRI-assisted cervix cancer brachytherapy pre-planning, based on application in paracervical anaesthesia : final report
Primož Petrič, Robert Hudej, Omar Hanuna, Primož Marolt, Barbara Šegedin, 2014, original scientific article

Abstract: Background. Optimal applicator insertion is a precondition for the success of cervix cancer brachytherapy (BT). We aimed to assess feasibility and efficacy of MRI-assisted pre-planning, based on applicator insertion in para-cervical anaesthesia (PCA). Patients and methods. Five days prior to BT, the pre-planning procedure was performed in 18 cervix cancer patients: tandem-ring applicator was inserted under PCA, pelvic MRI obtained and applicator removed. Procedure tolerability was assessed. High risk clinical target volume (HR CTV) and organs at risk were delineated on the pre-planning MRI, virtual needles placed at optimal positions, and dose planning performed. At BT, insertion was carried out in subarachnoidal anaesthesia according to pre-planned geometry. Pre-planned and actual treatment parameters were compared. Results. Pre-planning procedure was well tolerated. Median difference between the pre-planned and actual needle insertion depth and position were 2 (0%10) mm and 4 (0%30) degrees, respectively. The differences between the pre-planned and actual geometric and dosimetric parameters were statistically non-significant. All actual needles were positioned inside the HR CTV and outside the organs at risk (OAR). Conclusions. Our pre-planning approach is well tolerated and effective. Pre-planned geometry and dose distribution can be reproduced at BT.
Keywords: cervix cancer, pre-planning, image-guided brachytherapy
Published in DiRROS: 11.04.2024; Views: 193; Downloads: 80
.pdf Full text (753,88 KB)
This document has many files! More...

7.
8.
Assessment of local radial basis function collocation method for diffusion problems structured with multiquadrics and polyharmonic splines
Izaz Ali, Umut Hanoglu, Robert Vertnik, Božidar Šarler, 2024, original scientific article

Abstract: This paper aims to systematically assess the local radial basis function collocation method, structured with multiquadrics (MQs) and polyharmonic splines (PHSs), for solving steady and transient diffusion problems. The boundary value test involves a rectangle with Dirichlet, Neuman, and Robin boundary conditions, and the initial value test is associated with the Dirichlet jump problem on a square. The spectra of the free parameters of the method, i.e., node density, timestep, shape parameter, etc., are analyzed in terms of the average error. It is found that the use of MQs is less stable compared to PHSs for irregular node arrangements. For MQs, the most suitable shape parameter is determined for multiple cases. The relationship of the shape parameter with the total number of nodes, average error, node scattering factor, and the number of nodes in the local subdomain is also provided. For regular node arrangements, MQs produce slightly more accurate results, while for irregular node arrangements, PHSs provide higher accuracy than MQs. PHSs are recommended for use in diffusion problems that require irregular node spacing.
Keywords: meshless method, polyharmonic splines, multiquadrics, augmentation, heat diffusion equation
Published in DiRROS: 04.04.2024; Views: 193; Downloads: 66
.pdf Full text (2,79 MB)
This document has many files! More...

9.
Organic cathodes, a path toward future sustainable batteries : mirage or realistic future?
Jan Bitenc, Klemen Pirnat, Olivera Lužanin, Robert Dominko, 2024, review article

Published in DiRROS: 04.04.2024; Views: 196; Downloads: 78
.pdf Full text (4,74 MB)
This document has many files! More...

10.
Distance deviation measure of contouring variability
Peter Rogelj, Robert Hudej, Primož Petrič, 2013, original scientific article

Abstract: Background. Several methods that are currently used for contouring analysis have problems providing reliable and/ or meaningful results. In this paper a solution to these problems is proposed in a form of a novel measure, which was developed based on requirements defined for contouring studies. Materials and methods. The proposed distance deviation measure can be understood as an extension of the closest point measures in such a way that it does not measure only distances between points on contours but rather analyse deviation of distances to both/all contours from each image point/voxel. The obtained result is information rich, reliable and provided in a form of an image, enabling detailed topographic analysis. In addition to image representation, results can be further processed into angular representation for compact topographic analysis or into overall scalar estimates for quick assessment of contour disagreement. Results. Distance deviation method is demonstrated on a multi observer contouring example with complex contour shapes, i.e., with pronounced extremes and void interior. The results are presented using the three proposed methods. Conclusions. The proposed method can detect and measure contour variation irrespective of contour complexity and number of contour segments, while the obtained results are easy to interpret. It can be used in various situations, regarding the presence of reference contour or multiple test contours.
Keywords: contouring, contour comparison, distance transform
Published in DiRROS: 03.04.2024; Views: 207; Downloads: 43
.pdf Full text (938,42 KB)

Search done in 0.39 sec.
Back to top