<?xml version="1.0"?>
<metadata xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dc="http://purl.org/dc/elements/1.1/"><dc:title>Intra‐rater and inter‐rater reliability of robotic arthrometer DYNEELAX®</dc:title><dc:creator>Mihalinec,	Katja	(Avtor)
	</dc:creator><dc:creator>Martinez-Cepa,	Carmen B.	(Avtor)
	</dc:creator><dc:creator>Zuil-Escobar,	Juan C.	(Avtor)
	</dc:creator><dc:creator>Kejžar,	Nataša	(Avtor)
	</dc:creator><dc:creator>Vauhnik,	Renata	(Avtor)
	</dc:creator><dc:subject>anterior laxity</dc:subject><dc:subject>arthrometry</dc:subject><dc:subject>rotational laxity</dc:subject><dc:subject>reliability</dc:subject><dc:description>Purpose: The purpose of our study was to test the intra-rater and inter-rater reliability of the DYNEELAX® arthrometer in healthy subjects. Since rotational laxity will be measured for the first time in humans, indications for normative values will also be presented. Methods: Knee anterior laxity and rotational laxity using a DYNEELAX® arthrometer were assessed in 73 subjects (39 females and 34 males). An intraclass correlation coefficient was calculated to evaluate the intra-rater and inter-rater reliability of the DYNEELAX®. Results: An intraclass correlation coefficient for intra-rater reliability ranges from 0.631 (95% confidence interval; [CI]: 0.47–0.75) to 0.699 (95% CI: 0.56–0.80) and from 0.916 (95% CI: 0.87–0.95) to 0.94 (95% CI: 0.91–0.96) for anterior knee laxity and rotational knee laxity, respectively. An intraclass correlation coefficient for inter-rater reliability ranges from 0.578 (95% CI: 0.40–0.71) to 0.646 (95% CI: 0.44–0.78) and from 0.822 (95% CI: 0.57–0.91) to 0.933 (95% CI: 0.89–0.96) for anterior knee laxity and rotational knee laxity, respectively. Conclusions: The DYNEELAX® arthrometer has good to excellent intra-rater and inter-rater reliability for rotational knee laxity and moderate intra-rater reliability for anterior knee laxity in healthy subjects. Future studies should investigate the clinical significance of anterior and rotational laxity measured with the DYNEELAX® arthrometer in patients with knee pathology, as both laxities are critical for assessing the integrity of the intra-articular structures of the knee in clinical practice.</dc:description><dc:date>2024</dc:date><dc:date>2026-04-23 09:50:42</dc:date><dc:type>Neznano</dc:type><dc:identifier>29177</dc:identifier><dc:identifier>UDK: 615.82/.84:616.728.3</dc:identifier><dc:identifier>ISSN pri članku: 2197-1153</dc:identifier><dc:identifier>DOI: 10.1002/jeo2.70026</dc:identifier><dc:identifier>COBISS_ID: 209810179</dc:identifier><dc:language>sl</dc:language></metadata>
