Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "ključne besede" (design) .

1 - 6 / 6
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
Modelling intumescent coatings for the fire protection of structural systems : a review
Andrea Lucherini, Donatella de Silva, 2024, pregledni znanstveni članek

Povzetek: Purpose Intumescent coatings are nowadays a dominant passive system used to protect structural materials in case of fire. Due to their reactive swelling behaviour, intumescent coatings are particularly complex materials to be modelled and predicted, which can be extremely useful especially for performance-based fire safety designs. In addition, many parameters influence their performance, and this challenges the definition and quantification of their material properties. Several approaches and models of various complexities are proposed in the literature, and they are reviewed and analysed in a critical literature review. Design/methodology/approach Analytical, finite-difference and finite-element methods for modelling intumescent coatings are compared, followed by the definition and quantification of the main physical, thermal, and optical properties of intumescent coatings: swelled thickness, thermal conductivity and resistance, density, specific heat capacity, and emissivity/absorptivity. Findings The study highlights the scarce consideration of key influencing factors on the material properties, and the tendency to simplify the problem into effective thermo-physical properties, such as effective thermal conductivity. As a conclusion, the literature review underlines the lack of homogenisation of modelling approaches and material properties, as well as the need for a universal modelling method that can generally simulate the performance of intumescent coatings, combine the large amount of published experimental data, and reliably produce fire-safe performance-based designs. Research limitations/implications Due to their limited applicability, high complexity and little comparability, the presented literature review does not focus on analysing and comparing different multi-component models, constituted of many model-specific input parameters. On the contrary, the presented literature review compares various approaches, models and thermo-physical properties which primarily focusses on solving the heat transfer problem through swelling intumescent systems. Originality/value The presented literature review analyses and discusses the various modelling approaches to describe and predict the behaviour of swelling intumescent coatings as fire protection for structural materials. Due to the vast variety of available commercial products and potential testing conditions, these data are rarely compared and combined to achieve an overall understanding on the response of intumescent coatings as fire protection measure. The study highlights the lack of information and homogenisation of various modelling approaches, and it underlines the research needs about several aspects related to the intumescent coating behaviour modelling, also providing some useful suggestions for future studies.
Ključne besede: intumescent coatings, fire protection, modelling, structural fire engineering, fire safety, performance-based design
Objavljeno v DiRROS: 17.04.2024; Ogledov: 45; Prenosov: 11
.pdf Celotno besedilo (790,21 KB)
Gradivo ima več datotek! Več...

2.
Experimental investigation of the shear force capacity of prismatic cross laminated timber beams
Henrik Danielsson, Tomaž Pazlar, Erik Serrano, Boris Azinović, 2024, izvirni znanstveni članek

Povzetek: Experimental tests of Cross Laminated Timber (CLT) under in-plane beam loading conditions are presented. The influence of the element layup, the individual lamination width, and the beam overhang at the supports on the shear force capacity was investigated. All the CLT beams had the same gross cross section, and a 4-point-bending test setup was used. The experimentally determined load-bearing capacities are compared with the load-bearing capacities resulting from analytical methods proposed for structural design, focusing on shear failure in the crossing areas of flatwise bonded laminations (shear failure mode III). The test results indicate no or very small influence of the element layup and the lamination width on the shear force capacity. These results partly contradict the predictions of the proposed design methods. Of the three studied beam geometry parameters, the beam overhang at the support had the greatest influence on the load-bearing capacity.
Ključne besede: cross laminated timber, CLT, beam, shear testing, shear capacity, design methods
Objavljeno v DiRROS: 15.04.2024; Ogledov: 60; Prenosov: 29
.pdf Celotno besedilo (3,32 MB)
Gradivo ima več datotek! Več...

3.
4.
5.
6.
Kontinuiteta in spremembe Bienala oblikovanja
Cvetka Požar, 2014, strokovni članek

Ključne besede: design, grafično oblikovanje, industrijsko oblikovanje, skupinske razstave, Ljubljana
Objavljeno v DiRROS: 04.04.2018; Ogledov: 2449; Prenosov: 0

Iskanje izvedeno v 0.2 sek.
Na vrh