Digitalni repozitorij raziskovalnih organizacij Slovenije

Iskanje po repozitoriju
A+ | A- | Pomoč | SLO | ENG

Iskalni niz: išči po
išči po
išči po
išči po

Možnosti:
  Ponastavi


Iskalni niz: "avtor" (Hudej Robert) .

1 - 5 / 5
Na začetekNa prejšnjo stran1Na naslednjo stranNa konec
1.
MRI-assisted cervix cancer brachytherapy pre-planning, based on application in paracervical anaesthesia : final report
Primož Petrič, Robert Hudej, Omar Hanuna, Primož Marolt, Barbara Šegedin, 2014, izvirni znanstveni članek

Povzetek: Background. Optimal applicator insertion is a precondition for the success of cervix cancer brachytherapy (BT). We aimed to assess feasibility and efficacy of MRI-assisted pre-planning, based on applicator insertion in para-cervical anaesthesia (PCA). Patients and methods. Five days prior to BT, the pre-planning procedure was performed in 18 cervix cancer patients: tandem-ring applicator was inserted under PCA, pelvic MRI obtained and applicator removed. Procedure tolerability was assessed. High risk clinical target volume (HR CTV) and organs at risk were delineated on the pre-planning MRI, virtual needles placed at optimal positions, and dose planning performed. At BT, insertion was carried out in subarachnoidal anaesthesia according to pre-planned geometry. Pre-planned and actual treatment parameters were compared. Results. Pre-planning procedure was well tolerated. Median difference between the pre-planned and actual needle insertion depth and position were 2 (0%10) mm and 4 (0%30) degrees, respectively. The differences between the pre-planned and actual geometric and dosimetric parameters were statistically non-significant. All actual needles were positioned inside the HR CTV and outside the organs at risk (OAR). Conclusions. Our pre-planning approach is well tolerated and effective. Pre-planned geometry and dose distribution can be reproduced at BT.
Ključne besede: cervix cancer, pre-planning, image-guided brachytherapy
Objavljeno v DiRROS: 11.04.2024; Ogledov: 89; Prenosov: 31
.pdf Celotno besedilo (753,88 KB)
Gradivo ima več datotek! Več...

2.
Distance deviation measure of contouring variability
Peter Rogelj, Robert Hudej, Primož Petrič, 2013, izvirni znanstveni članek

Povzetek: Background. Several methods that are currently used for contouring analysis have problems providing reliable and/ or meaningful results. In this paper a solution to these problems is proposed in a form of a novel measure, which was developed based on requirements defined for contouring studies. Materials and methods. The proposed distance deviation measure can be understood as an extension of the closest point measures in such a way that it does not measure only distances between points on contours but rather analyse deviation of distances to both/all contours from each image point/voxel. The obtained result is information rich, reliable and provided in a form of an image, enabling detailed topographic analysis. In addition to image representation, results can be further processed into angular representation for compact topographic analysis or into overall scalar estimates for quick assessment of contour disagreement. Results. Distance deviation method is demonstrated on a multi observer contouring example with complex contour shapes, i.e., with pronounced extremes and void interior. The results are presented using the three proposed methods. Conclusions. The proposed method can detect and measure contour variation irrespective of contour complexity and number of contour segments, while the obtained results are easy to interpret. It can be used in various situations, regarding the presence of reference contour or multiple test contours.
Ključne besede: contouring, contour comparison, distance transform
Objavljeno v DiRROS: 03.04.2024; Ogledov: 57; Prenosov: 16
.pdf Celotno besedilo (938,42 KB)

3.
4.
5.
3D-brahiterapija raka materničnega vratu na podlagi magnetnoresonančnega slikanja
Primož Petrič, Robert Hudej, Maja Marolt-Mušič, 2008, strokovni članek

Objavljeno v DiRROS: 31.08.2018; Ogledov: 3448; Prenosov: 842
.pdf Celotno besedilo (481,05 KB)

Iskanje izvedeno v 0.15 sek.
Na vrh